Safe rooms and shelters: Protecting People Against Terrorist Attacks

Safe rooms and shelters: Protecting People Against Terrorist Attacks
Author:
Publisher: Government Printing Office
Total Pages: 268
Release:
Genre: Business & Economics
ISBN: 9780160876561

NOTE: NO FURTHER DISCOUNT FOR THIS PRINT PRODUCT -- OVERSTOCK SALE -- Significantly reduced list price while supplies last This manual is intended to provide guidance for engineers, architects, building officials, building and home inspectors, and property owners to design shelters and safe rooms n buildings. It presents informaton about the design and construction of shelters in the work place, home, or community building that will provide protection in response to manmade hazards. Included is information to: assist in planning and design of shelters that may be constructed outside or within dwellings or public buildings. designed to protect individuals from assaults and attempted kidnapping, which requires design featurs to resist forced entry and ballistic impact Protective options, from low-cost expedient protection, such as sheltering-in-place to safe rooms ventilated and pressurized with purified air by ultra-high- efficiency filters. and more. Related products: Taking Shelter From the Storm: Building a Safe Room for Your Home or Small Business; Includes Construction Plans (CD) can be found here: https: //bookstore.gpo.gov/products/sku/064-000-00069-1?ctid=138 A Study of Active Shooter Incidents in the United States Between 2000 and 2013 can be found here: https: //bookstore.gpo.gov/products/sku/027-001-00101-3 Incremental Protection for Existing Commercial Buildings From Terrorist Attack: Providing Protection to People and Buildings can be found here: https: //bookstore.gpo.gov/products/sku/064-000-00043-8 Reference Manual to Mitigate Potential Terrorist Attacks Against Buildings: Providing Protection to People and Buildings is available here: https: //bookstore.gpo.gov/products/sku/064-000-00038-1 World Trade Center Building Performance Study: Data Collection, Preliminary Observations, and Recommendations is available here: https: //bookstore.gpo.gov/products/sku/064-000-00029-2 Other products produced by U.S. Federal Emergency Management Agency (FEMA) can be found here: https: //bookstore.gpo.gov/agency/528

Risk Management Series: Safe Rooms and Shelters - Protecting People Agains Terrorist Attacks

Risk Management Series: Safe Rooms and Shelters - Protecting People Agains Terrorist Attacks
Author: Federal Emergency Agency
Publisher: FEMA
Total Pages: 264
Release: 2013-01-26
Genre: Social Science
ISBN:

This manual is intended to provide guidance for engineers, architects, building officials, and property owners to design shelters and safe rooms in buildings. It presents information about the design and construction of shelters in the work place, home, or community building that will provide protection in response to manmade hazards. The information contained herein will assist in the planning and design of shelters that may be constructed outside or within dwellings or public buildings. These safe rooms will protect occupants from a variety of hazards, including debris impact, accidental or intentional explosive detonation, and the accidental or intentional release of a toxic substance into the air. Safe rooms may also be designed to protect individuals from assaults and attempted kidnapping, which requires design features to resist forced entry and ballistic impact. This covers a range of protective options, from low-cost expedient protection (what is commonly referred to as sheltering-in-place) to safe rooms ventilated and pressurized with air purified by ultra-high-efficiency filters. These safe rooms protect against toxic gases, vapors, and aerosols. The contents of this manual supplement the information provided in FEMA 361, Design and Construction Guidance for Community Shelters and FEMA 320, Taking Shelter From the Storm: Building a Safe Room Inside Your House. In conjunction with FEMA 361 and FEMA 320, this publication can be used for the protection of shelters against natural disasters. This guidance focuses on safe rooms as standby systems, ones that do not provide protection on a continuous basis. To employ a standby system requires warning based on knowledge that a hazardous condition exists or is imminent. Protection is initiated as a result of warnings from civil authorities about a release of hazardous materials, visible or audible indications of a release (e.g., explosion or fire), the odor of a chemical agent, or observed symptoms of exposure in people. Although there are automatic detectors for chemical agents, such detectors are expensive and limited in the number of agents that can be reliably detected. Furthermore, at this point in time, these detectors take too long to identify the agent to be useful in making decisions in response to an attack. Similarly, an explosive vehicle or suicide bomber attack rarely provides advance warning; therefore, the shelter is most likely to be used after the fact to protect occupants until it is safe to evacuate the building. Two different types of shelters may be considered for emergency use, standalone shelters and internal shelters. A standalone shelter is a separate building (i.e., not within or attached to any other building) that is designed and constructed to withstand the range of natural and manmade hazards. An internal shelter is a specially designed and constructed room or area within or attached to a larger building that is structurally independent of the larger building and is able to withstand the range of natural and manmade hazards. Both standalone and internal shelters are intended to provide emergency refuge for occupants of commercial office buildings, school buildings, hospitals, apartment buildings, and private homes from the hazards resulting from a wide variety of extreme events. The shelters may be used during natural disasters following the warning that an explosive device may be activated, the discovery of an explosive device, or until safe evacuation is established following the detonation of an explosive device or the release of a toxic substance via an intentional aerosol attack or an industrial accident. Standalone community shelters may be constructed in neighborhoods where existing homes lack shelters. Community shelters may be intended for use by the occupants of buildings they are constructed within or near, or they may be intended for use by the residents of surrounding or nearby neighborhoods or designated areas.

Home Builder's guide to coastal construction

Home Builder's guide to coastal construction
Author: Federal Emergency Management Agency
Publisher: Government Printing Office
Total Pages: 184
Release: 2012-10-15
Genre: Architecture
ISBN: 9780160914133

NOTE: NO FURTHER DISCOUNT FOR THIS PRINT PRODUCT -- OVERSTOCK SALE -- Signficantly reduced lsit price FEMA produced this series of 37 fact sheets to provide technical guidance and recommendations concerning the construction of coastal residential buildings. The fact sheets present information aimed at improving the performance of buildings subject to flood and wind forces in coastal environments. Photographs and drawings illustrate National Flood Insurance Program (NFIP) regulatory requirements, the proper siting of coastal buildings, and recommended design and construction practices for building components, including structural connections, the building envelope, and utilities. Many of the fact sheets also include lists of FEMA and other resources that provide more information about the topics discussed. Where appropriate, resources are accompanied by active web links. A list of the individual fact sheets that are contained inFEMA P-499, follows.Category 1 GeneralFact Sheet No. 1.1, Coastal Building Successes and FailuresFact Sheet No. 1.2, Summary of Coastal Construction Requirements and RecommendationsFact Sheet No. 1.3, Using a Flood Insurance Rate Map (FIRM)Fact Sheet No. 1.4, Lowest Floor ElevationFact Sheet No. 1.5, V-Zone Design and Construction CertificationFact Sheet No. 1.6, Designing for Flood Levels Above the BFEFact Sheet No. 1.7, Coastal Building MaterialsFact Sheet No. 1.8, Non-Traditional Building Materials and SystemsFact Sheet No. 1.9, Moisture Barrier Systems Category 2 Planning Fact Sheet No. 2.1, How Do Siting and Design Decisions Affect the Owner's Costs?Fact Sheet No. 2.2, Selecting a Lot and Siting the Building Category 3 Foundations Fact Sheet No. 3.1, Foundations in Coastal AreasFact Sheet No. 3.2, Pile InstallationFact Sheet No. 3.3, Wood-Pile-to-Beam ConnectionsFact Sheet No. 3.4, Reinforced Masonry Pier ConstructionFact Sheet No. 3.5, Foundation Walls Category 4 Load Paths Fact Sheet No. 4.1, Load PathsFact Sheet No. 4.2, Masonry DetailsFact Sheet No. 4.3, Use of Connectors and Brackets Category 5 Wall Systems Fact Sheet No. 5.1, HousewrapFact Sheet No. 5.2, Roof-to-Wall and Deck-to-Wall FlashingFact Sheet No. 5.3, Siding Installation in High-Wind RegionsFact Sheet No. 5.4, Attachment of Brick Veneer In High-Wind Regions Category 6 Openings Fact Sheet No. 6.1, Window and Door InstallationFact Sheet No. 6.2, Protection of Openings Shutters and Glazing Category 7 - Roofing Fact Sheet No. 7.1, Roof Sheathing InstallationFact Sheet No. 7.2, Roof Underlayment for Asphalt Shingle RoofsFact Sheet No. 7.3, Asphalt Shingle Roofing for High-Wind RegionsFact Sheet No. 7.4, Tile Roofing for High-Wind AreasFact Sheet No. 7.5, Minimizing Water Intrusion through Roof Vents in High-Wind RegionsFact Sheet No. 7.6, Metal Roof Systems in High-Wind Regions Category 8 Attachments Fact Sheet No. 8.1, Enclosures and Breakaway WallsFact Sheet No. 8.2, Decks, Pools, and Accessory StructuresFact Sheet No. 8.3, Protecting Utilities Category 9 Repairs Fact Sheet No. 9.1, Repairs, Remodeling, Additions, and Retrofitting FloodFact Sheet No. 9.2, Repairs, Remodeling, Additions, and Retrofitting Wind Category G Guide Fact Sheet No. G.1, Technical Fact Sheet GuideFact Sheet No. G.2, References and Resources"