Time Of Flight Secondary Ion Mass Spectrometry
Download Time Of Flight Secondary Ion Mass Spectrometry full books in PDF, epub, and Kindle. Read online free Time Of Flight Secondary Ion Mass Spectrometry ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads. We cannot guarantee that every ebooks is available!
Author | : Sarah Fearn |
Publisher | : Morgan & Claypool Publishers |
Total Pages | : 67 |
Release | : 2015-10-16 |
Genre | : Technology & Engineering |
ISBN | : 1681740885 |
This book highlights the application of Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) for high-resolution surface analysis and characterization of materials. While providing a brief overview of the principles of SIMS, it also provides examples of how dual-beam ToF-SIMS is used to investigate a range of materials systems and properties. Over the years, SIMS instrumentation has dramatically changed since the earliest secondary ion mass spectrometers were first developed. Instruments were once dedicated to either the depth profiling of materials using high-ion-beam currents to analyse near surface to bulk regions of materials (dynamic SIMS), or time-of-flight instruments that produced complex mass spectra of the very outer-most surface of samples, using very low-beam currents (static SIMS). Now, with the development of dual-beam instruments these two very distinct fields now overlap.
Author | : J. C. Vickerman |
Publisher | : IM Publications |
Total Pages | : 742 |
Release | : 2013 |
Genre | : Mass spectrometry |
ISBN | : 1906715173 |
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is the most versatile of the surface analysis techniques that have been developed during the last 30 years. This is the Second Edition of the first book ToF-SIMS: Surface analysis by Mass Spectrometry to be dedicated to the subject and the treatment is comprehensive
Author | : Alan M. Spool |
Publisher | : Momentum Press |
Total Pages | : 267 |
Release | : 2016-03-24 |
Genre | : Technology & Engineering |
ISBN | : 1606507745 |
Time of flight secondary ion mass spectrometry, TOF-SIMS, is a highly surface sensitive analytical technique that provides information about composition with submicron lateral resolution. For select materials, TOF-SIMS provides unparalleled sensitivity along with excellent reproducibility, and as a mass spectrometric technique, it also provides excellent specificity. Of the analytical methods available, it is among the most surface sensitive, but the physical principles that underlie it are also the least understood. This volume describes the instrumentation, the physical principles behind the technique to the extent they are understood, and provides a practical approach for the interpretation of TOF-SIMS data. The use of advanced data processing methods such as multivariate statistics are described in a readily approachable manner. Given a basic background in undergraduate chemistry and physics, the book will be of use to any student with an interest in the technique.
Author | : Daniele Benoit |
Publisher | : Springer Science & Business Media |
Total Pages | : 628 |
Release | : 2012-12-06 |
Genre | : Science |
ISBN | : 3709165555 |
The European Microanalysis Society held its Fourth Workshop in Saint Malo in May 1995. This volume includes the revised presentations, 10 tutorial chapters and 50 brief articles, from leading experts in electron probe microanalysis, secondary mass spectroscopy, analytical electron microscopy, and related fields.
Author | : S Fearn |
Publisher | : Myprint |
Total Pages | : 68 |
Release | : 2015-10-05 |
Genre | : |
ISBN | : 9781681747385 |
Author | : Alfred Benninghoven |
Publisher | : Springer Science & Business Media |
Total Pages | : 578 |
Release | : 2012-12-06 |
Genre | : Science |
ISBN | : 3642827241 |
This volume contains the proceedings of the Fifth International Confer ence on Secondary Ion Mass Spectrometry (SIMS V), held at the Capitol Holiday Inn, Washington, DC, USA, from September 30 to October 4, 1985. The conference was the fifth in a series of conferences held bienni ally. Previous conferences were held in Miinster (1977), Stanford (1979), Budapest (1981), and Osaka (1983). SIMS V was organized by Dr. R.J. Colton of the Nayal Research Lab oratory and Dr. D.S. Simons of the National Bureau of Standards un der the auspices of the International Organizing Committee chaired by Prof. A. Benninghoven of the Universitat Miinster. Dr. Richard F.K. Herzog served as the honorary chairman of SIMS V. While Dr. Herzog is best known to the mass spectrometry community for his theoretical development of a mass spectrometer design, known as the Mattauch-Herzog geometry, he also made several early and impor tant contributions to SIMS. In 1949, Herzog and Viehbock published a description of the first instrument designed to study secondary ions pro duced by bombardment from a beam of ions generated in a source that was separated from the sample by a narrow tube. Later at the GCA Cor poration, he brought together a team of researchers including H.J. Liebl, F.G. Riidenauer, W.P. Poschenrieder and F.G. Satkiewicz, who designed and built, and carried out applied research with the first commercial ion microprobe.
Author | : Fred Stevie |
Publisher | : Momentum Press |
Total Pages | : 233 |
Release | : 2015-09-15 |
Genre | : Technology & Engineering |
ISBN | : 1606505890 |
This book was written to explain a technique that requires an understanding of many details in order to properly obtain and interpret the data obtained. It also will serve as a reference for those who need to provide SIMS data. The book has over 200 figures and the references allow one to trace development of SIMS and understand the many details of the technique.
Author | : Danica Heller-Krippendorf |
Publisher | : Springer Nature |
Total Pages | : 195 |
Release | : 2019-10-31 |
Genre | : Science |
ISBN | : 3658285028 |
Danica Heller-Krippendorf develops concepts and approaches optimizing the applicability of MVA on data sets from an industrial context. They enable more time-efficient MVA of the respective ToF‐SIMS data. Priority is given to two main aspects by the author: First, the focus is on strategies for a more time-efficient collection of the input data. This includes the optimal selection of the number of replicate measurements, the selection of input data and guidelines for the selection appropriate data preprocessing methods. Second, strategies for more efficient analysis of MVA results are presented. About the Author: Danica Heller-Krippendorf did her research and dissertation at the University of Siegen, Germany, in collaboration with a German analytical service company. Now she is engineer in analytics at a DAX company.
Author | : Freddy Adams |
Publisher | : Elsevier |
Total Pages | : 493 |
Release | : 2015-06-06 |
Genre | : Science |
ISBN | : 0444634509 |
Chemical Imaging Analysis covers the advancements made over the last 50 years in chemical imaging analysis, including different analytical techniques and the ways they were developed and refined to link the composition and structure of manmade and natural materials at the nano/micro scale to the functional behavior at the macroscopic scale. In a development process that started in the early 1960s, a variety of specialized analytical techniques was developed – or adapted from existing techniques – and these techniques have matured into versatile and powerful tools for visualizing structural and compositional heterogeneity. This text explores that journey, providing a general overview of imaging techniques in diverse fields, including mass spectrometry, optical spectrometry including X-rays, electron microscopy, and beam techniques. - Provides comprehensive coverage of analytical techniques used in chemical imaging analysis - Explores a variety of specialized techniques - Provides a general overview of imaging techniques in diverse fields
Author | : Dietmar Stapel |
Publisher | : |
Total Pages | : 85 |
Release | : 2000 |
Genre | : |
ISBN | : |