Improvement Installation And Testing Of A Monte Carlo Based Treatment Planning System Pcbplan For Boron Neutron Capture Therapy
Download Improvement Installation And Testing Of A Monte Carlo Based Treatment Planning System Pcbplan For Boron Neutron Capture Therapy full books in PDF, epub, and Kindle. Read online free Improvement Installation And Testing Of A Monte Carlo Based Treatment Planning System Pcbplan For Boron Neutron Capture Therapy ebook anywhere anytime directly on your device. Fast Download speed and no annoying ads. We cannot guarantee that every ebooks is available!
Author | : Detlef Gabel |
Publisher | : Springer Science & Business Media |
Total Pages | : 274 |
Release | : 2012-12-06 |
Genre | : Medical |
ISBN | : 1461534089 |
The European Collaboration on Boron Neutron Capture Therapy (BNCT), conceived in 1987 and successful in 1989 in gaining financial support as a Concerted Action through the Medical and Health Research Programme of the Commission ofthe European Communities (CEC) in Brussels, considered it an opportune moment to hold its annual Plenary Meeting on 18-20 Septem ber 1991 as an International Workshop entitled "Towards Clinical Trials of Glioma with BNCT". The background to this consideration was influenced by the world-wide resurgence ofinterest in NCT over the last 2 decades and by the exemplifica tions at the Fourth International Symposium on Neutron Capture Therapy for Cancer held in Sydney in December 1990, where it was strongly indicated that within the next 2 years clinical trials would be started both in Europe and the United States. In particular at the High Flux Reactor of the Joint Research Centre of the CEC at Petten in The Netherlands, an epithermal neutron beam designed and installed in the summer of 1990 recently became operable at full reactor power. An extensive series ofexperiments, including the nuclear and radiobiological characterisation of the beam and a healthy tissue tolerance study on canines has started and has the aim to define the preconditions for clinical trials onpatients with Grade III/IV glioma. However, as with any other new therapy modality, it must be demon strated that BNCT is safe for the patient and has a reasonable chance of being an effective therapy.
Author | : H. Zaidi |
Publisher | : CRC Press |
Total Pages | : 394 |
Release | : 2002-09-01 |
Genre | : Medical |
ISBN | : 9781420033250 |
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. With chapters written by recognized authorit
Author | : Martin Siggel |
Publisher | : |
Total Pages | : 128 |
Release | : 2012 |
Genre | : |
ISBN | : |
Author | : International Atomic Energy Agency |
Publisher | : IAEA |
Total Pages | : 61 |
Release | : 2007 |
Genre | : Medical |
ISBN | : 9789201027078 |
This publication serves as a protocol to be used by both manufacturers and users for the specification and acceptance testing of radiotherapy treatment planning systems (RTPSs). Recommendations are provided in this report for specific tests to be performed at the manufacturing facility and acceptance tests to be performed at the radiotherapy hospital. The protocol uses the IEC 62083 standard as its basis for defining the specifications and acceptance tests. The analysis of algorithm site testing does not only test for consistency with the factory type tests but will also help the user at the hospital to understand how well the algorithm works and what kind of results should be expected