Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Third Quarter, Calendar Year 1995

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Third Quarter, Calendar Year 1995
Author:
Publisher:
Total Pages: 94
Release: 1995
Genre:
ISBN:

The INEL Radiological Control Performance Indicator Report is provided quarterly, in accordance with Article 133 of the INEL Radiological Control Manual. Indicators are used as a measure of performance of the Radiological Control Program and as a motivation for improvement, not as a goal in themselves. These indicators should be used by management to assist in focusing priorities and attention and adherence to As-Low-As-Reasonably-Achievable (ALARA) practices. The INEL Radiological Control Performance Indicators consist of: collective dose in person-rem; average work dose, maximum dose to a worker, and maximum neutron dose to a worker; the number of skin and clothing contaminations, including the number of contaminated wounds and facial contaminations; the number of radioactive material intakes resulting in a dose assessment of 10 mrem or more; the area of contamination, high contamination, and airborne radioactivity areas in square feet; and airborne radioactivity events and spills.

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Fourth Quarter -- Year-end Report, Calendar Year 1995

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Fourth Quarter -- Year-end Report, Calendar Year 1995
Author:
Publisher:
Total Pages: 94
Release: 1996
Genre:
ISBN:

The INEL Radiological Control Performance Indicator Report is comprised of a description of the indicator and the criteria used for measurement. Indicators evaluated in this report include: collective radiation dose; average worker radiation dose; maximum radiation dose to a worker; maximum neutron dose to a worker; number of skin contaminations; number of clothing contaminations; airborne events; total radiological intakes; contamination areas; high contamination area; airborne radioactivity area; and radioactive spills.

Idaho National Engineering and Environmental Laboratory Radiological Control Performance Indicator Report - Third Quarter - Calendar Year 1998

Idaho National Engineering and Environmental Laboratory Radiological Control Performance Indicator Report - Third Quarter - Calendar Year 1998
Author:
Publisher:
Total Pages: 62
Release: 1998
Genre:
ISBN:

The INEEL Radiological Control Performance Indicator Report is provided quarterly, in accordance with Article 133 of the INEEL Radiological Control Manual. Indicators are used to measure performance of the Radiological Control Program and as a motivation for improvement, not as goals in themselves. These indicators should be used by management as tools to focus on priorities, attention, and adherence to As-Low-As-Reasonably-Achievable (ALARA) practices. This document provides a report and an analysis of the Radiological Control Program through the third quarter of Calendar Year 1998 (CY-98) for Lockheed Martin Idaho Technologies Company (LMITCO). This Performance Indicator Report is provided in accordance with Article 133 of the INEEL Radiological Control Manual. The LMITCO collective occupational radiation deep dose is 47.0 person-rem year to date, compared to a year to date goal of 65.8 person-rem.

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Fourth Quarterly Calendar Year 1994

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Fourth Quarterly Calendar Year 1994
Author:
Publisher:
Total Pages: 22
Release: 1995
Genre:
ISBN:

This document provides a report and analysis of the Radiological Control Program through the fourth quarter of calendar year 1994 (CY-1994) at the Idaho National Engineering Laboratory (INEL) under the direction of Lockheed Idaho Technologies Company (LITCO). The Radiological Performance Indicator Report is provided in accordance with Article 133 of the INEL Radiological Control Manual.

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report

Idaho National Engineering Laboratory Radiological Control Performance Indicator Report
Author:
Publisher:
Total Pages: 101
Release: 1996
Genre:
ISBN:

The INEL Radiological Control Performance Indicator Report is provided quarterly, in accordance with Article 133 of the INEL Radiological Control Manual. Indicators are used as a measure of performance of the Radiological Control Program and as a motivation for improvement, not as a goal in themselves. These indicators should be used by management to assist in focusing priorities and attention and adherence to As-Low-As-Reasonably-Achievable (ALARA) practices. The INEL Radiological Control Performance Indicators consist of: collective dose in person-rem; average worker dose, maximum dose to a worker, and maximum neutron dose equivalent to a worker; number of skin and clothing contaminations, including the number of contaminated wounds and facial contaminations; number of radioactive material intakes resulting in a dose assessment of 10 mrem or more; area of contamination, high contamination, and airborne radioactivity areas, in square feet; and airborne radioactivity events and spills.

Idaho National Engineering and Environmental Laboratory Radiological Control Performance Indicator Report - First Quarter, Calendar Year 1999

Idaho National Engineering and Environmental Laboratory Radiological Control Performance Indicator Report - First Quarter, Calendar Year 1999
Author:
Publisher:
Total Pages:
Release: 1999
Genre:
ISBN:

This Performance Indicator Report is provided in accordance with Article 133 of the INEEL Radiological Control Manual. The INEEL collective occupational radiation deep dose is 63.034 person-rem year to date, compared to a goal of 83.1 person-rem. During the fourth quarter, all areas experienced deletions of work resulting from the Maintenance Stand Down. This reduction in work is a primary factor in the difference in the year end dose and the ALARA goal. The work will be completed during CY-99. Beginning in CY-98, a numeric Radiological Performance Index (RPI) is being used to compare radiological performance. The RPI takes into consideration frequency and severity of events such as skin contaminations, clothing contaminations, spills, exposures to radiation exceeding limits, and positive internal dose. The RPI measures the cost of these events in cents per hour of radiological work performed. To make the RPI meaningful, tables have been prepared to show the facility that contributes to the values used. The data are compared on a quarterly basis to the prior year to show measurable performance.