Flight- and Ground-test Evaluation of Pyrrone Foams

Flight- and Ground-test Evaluation of Pyrrone Foams
Author: Allen G. McLain
Publisher:
Total Pages: 44
Release: 1972
Genre: Ablative materials
ISBN:

Two Pyrrone materials, pure Pyrrone foam with a density of 481 kg/cu m and hollow glass microsphere-Pyrrone composite with a density of 962 kg/cu m, were tested in the Langley 20-inch hypersonic arc heated tunnel at pressure levels from 0.06 to 0.27 atm and heating rates from 1.14 to 11.4 MW/sq m. The 481-kg/cu m Pyrrone foam was also flight tested as an experiment aboard a Pacemaker test vehicle. The results of the ground tests indicated that the thermal effectiveness of the 481-kg/cu m Pyrrone foam was superior to the 962-kg/cu m glass sphere-Pyrrone composite. The 481-kg/cu m Pyrrone foam had approximately one-half the thermal effectiveness of low density phenolic nylon. The 481-kg/cu m Pyrrone foam experienced random mechanical char removal over the entire range of test conditions. Char thermal property inputs for an ablation computer program were developed from the ground test data of the 481-kg/cu m Pyrrone foam. The computer program using these developed char thermal properties, as well as the measured uncharred material properties, adequately predicted the in-depth temperature histories measured during the Pacemaker flight.

Flight and Ground Tests of a Very-low-density Elastomeric Ablative Material

Flight and Ground Tests of a Very-low-density Elastomeric Ablative Material
Author: George C. Olsen
Publisher:
Total Pages: 44
Release: 1972
Genre: Ablation (Aerothermodynamics)
ISBN:

A very low density ablative material, a silicone-phenolic composite, was flight tested on a recoverable spacecraft launched by a Pacemaker vehicle system; and, in addition, it was tested in an arc heated wind tunnel at three conditions which encompassed most of the reentry heating conditions of the flight tests. The material was composed, by weight, of 71 percent phenolic spheres, 22.8 percent silicone resin, 2.2 percent catalyst, and 4 percent silica fibers. The tests were conducted to evaluate the ablator performance in both arc tunnel and flight tests and to determine the predictability of the albator performance by using computed results from an existing one-dimensional numerical analysis. The flight tested ablator experienced only moderate surface recession and retained a smooth surface except for isolated areas where the char was completely removed, probably following reentry and prior to or during recovery. Analytical results show good agreement between arc tunnel and flight test results. The thermophysical properties used in the analysis are tabulated.